Study on Active Control using Regenerated Vibration Energy.
スポンサーリンク
概要
- 論文の詳細を見る
A method of active control using regenerated vibration energy is proposed. Typical active control consumes energy, which is one of drawbacks of active control. However, in the proposed active-energy regenerative hybrid control system, all of the energy for the actuator is supplied from an energy regenerative damper. For the control law of active control, the concept of sky hook control is applied. From experiments and numerical simulations, it is found that the proposed system could act as an isolator and it is expected to exhibit better isolation performance than a passive or semi-active controller.