Performance Estimation Simulation of Capsule-Type Thermal Eenrgy Storage System. In-line Arranged Cylindrical Capsules.
スポンサーリンク
概要
- 論文の詳細を見る
Using the bypass controlling method, the outlet temperature from an energy storage tank is obtained as required. In this paper, a numerical method simulating the response of the storage tank is proposed. The models show good agreement with experimental data. Then the performance is estimated by the amount of energy necessary to obtain the required temperature. The efficiency is shown as a function of the total flow rate and the required temperature. The effects of the capsule array and capsule size on the performance are discussed. Finally the effects of the heat transfer promotion of the inside and/or outside of the capsules on the total performance are discussed.