Studies for Analyzing the Prohibited Ingredients Such as Vitamin L1 and Pilocarpine Hydrochloride in Cosmetics.
スポンサーリンク
概要
- 論文の詳細を見る
We have already reported the analytical method of procaine hydrochloride and dibucaine hydrochloride (prohibited in cosmetics on the public comment of Ministry of Health and Welfare of Japanese Government in 1986). In order to find out another prohibited ingredients in cosmetics, we estimated the analytical method of vitamin L1 and pilocarpine hydrochloride by HPLC. Vitamin L1 and pilocarpine hydrochloride in the lotions or milky lotions were extracted with methanol. The extract was analyzed by HPLC using the column (Shiseido CAPCELL PAK C18, 4.6×250mm) and a mixture of acetonitrile and 50mM phosphate buffer (pH 5) (37:3) or (19:1) for vitamin L1 and pilocarpine hydrochloride were used. The detection wavelength of vitamin L1 and pilocarpine hydrochloride were at 244 and 214nm, respectively. By the use of the above analytical method we made it sure that vitamin L1 and pilocarpine hydrochloride could be determined without the interference of the ingredients.
- 日本化粧品技術者会の論文
日本化粧品技術者会 | 論文
- 加齢臭発生機序に基づく対処商品の開発
- ヒトのくせ毛の微細構造
- 触動作の特徴抽出による化粧品の使用感評価--スキンケア製品の塗布動作
- 新規カチオン性ポリマーの開発とその応用
- 顔面頬部位立体形状の加齢変化