Program for Photon Shielding Calculations:Examination of Approximations on Irradiation Geometries
スポンサーリンク
概要
- 論文の詳細を見る
Penetration factors and related numerical data in "Manual of Practical Shield Calculation of Radiation Facilities (2000)", which correspond to the irradiation geometries of point isotropic source in infinite thick material (PI), point isotropic source in finite thick material (PF) and vertical incident to finite thick material (VF), have been carefully examined. The shield calculation based on the PI geometry is usually performed with effective dose penetration factors of radioisotopes given in the "manual". The present work clearly shows that such a calculation may lead to an overestimate more than twice larger, especially for thick shield of concrete and water.<BR>Employing the numerical data in the "manual", we have fabricated a simple computer program for the estimation of penetration factors and effective doses of radioisotopes in the different irradiation geometries, i.e., PI, PF and VF. The program is also available to calculate the effective dose from a set of radioisotopes in the different positions, which is necessary for the γ-ray shielding of radioisotope facilities.
- 日本放射線安全管理学会の論文
日本放射線安全管理学会 | 論文
- イメージングプレートに記録されたPSL強度分布の解析
- イメージングプレートにおけるPSL強度分布に着目した線種識別法の提案
- 線量当量(Dose Equivalent)と等価線量(Equivalent Dose)
- 広帯域エネルギー対応マルチ放射線モニタDARWINの開発 (第4回JPSMシンポジウム) -- (先端放射線計測技術と放射線安全管理--測定の自動化と広帯域化)
- 半導体式電子ポケット線量計の経年変化と方向特性