Clinical Application of a CT-Guided Lung Biopsy System: Core Needle Biopsy at the IVR Center.
スポンサーリンク
概要
- 論文の詳細を見る
Prior reports of CT-guided lung biopsy of the small lung nodules of less than 2 cm have been unsatisfactory. In January 1998, we began a preliminary study of CT-guided lung biopsy in our conventional CT room. With the basic results achieved, we constructed a novel CT-guided lung biopsy system.Together with Hitachi Corporation we have developed CT, the Radix Prima, exclusive for interventional procedures especially for CT-guided lung biopsy. As reconstruction delay time of the procedures has been shortened from 1.0 sec. to 0.6 sec. , real time CT fluoroscopy monitoring is possible on the Cathode Ray Tube (CRT) monitor in the CT room, very closed to the patient. Multiple confirmations of the tip of the biopsy needle have been possible with this specially equipped CT. A semi-automatic-type needle have been selected for reliable biopsy, because the old fully-automatic-type needle was very heavy and easily misfired. Multiple punctures have been also used, because single punctures have a greater risk of obtaining inadequate specimens.In our clinical study at our IVR center, the subjects comprised 41 patients (26 males, 15 females, ranging in age from 34 to 79, mean 64 years old). The mean nodule diameter was 1.9 cm, the mean distance from skin surface to lesion was 5.5 cm, and the mean number of punctures was 3.0. The biopsy results included 23 malignancies. In 13 patients the results were benign tumors or specific inflammation. In 4 patients the results were nonspecific inflammation. In only 1 patient was the specimen inadequate. There was no false negative. The correct rate of benign/malignant diagnoses was 98%. A complication of pneumothorax was observed in 22 patients, but all were improved by conservative treatment. Pulmonary hemorrhage was observed in 21 patients, 7 of whom also had hemoptysis. Each of these patients also responded to conservative treatment from specialist medical staff at the IVR center.The 98%accuracy of our results indicates that multiple punctures using a semi-automatic-type biopsy needle and multiple confirmations of the needle tip on our method of real time CT fluoroscopy are extremely important for CT-guided lung biopsy of small lung nodules of less than 2 cm.
- 日本医科大学医学会の論文
日本医科大学医学会 | 論文
- わが国における腸チフスの疫学的考察--1973年〜1976年届出菌検出例を中心として
- 臨床および実験報告 二絨毛膜双胎妊娠における高年初産の検討
- 救急災害医学の確立と展望[含 略歴 研究業績] (定年退職教授記念講演会講演要旨)
- 臨床のために 関節リウマチの診断と治療
- TNFファミリーの制御による関節リウマチ治療の可能性 (特集 第15回公開「シンポジウム」(アレルギー・膠原病に対する新たな展開))