Peripheral Directional Atherectomy Evaluated with a Rotational Digital Angiography System.
スポンサーリンク
概要
- 論文の詳細を見る
Background: One of the factors that affect the recurrence rate after peripheral directional atherectomy (DA) is the degree of residual stenosis. A new method of peripheral DA to reduce residual stenoses was evaluated with a rotational digital angiography (RDA) system that provides both angiography and fluoroscopy at multiple projections within 360 degrees.<BR> Patients and methods: Between March 1995 and July 1999, severe short segmental stenoses of six iliac arteries and two superficial femoral arteries (SFA) in eight patients were treated with the Simpson DA catheter under RDA system guidance. After pre-procedural RDA evaluation, the first series of DA were performed under ordinary PA fluoroscopic guidance. The residual stenoses were evaluated with RDA. If the residual stenoses exceeded 30%, a second series of DA were performed covering the residual plaque with the cutter window of the DA catheter. To this purpose the fluoroscopy of the RDA system was fixed in the direction in which the residual stenoses were largest and most eccentric. The end point was defined to be a residual stenosis of less than 30% evaluated with the RDA system, and the procedures were repeated until the end point was achieved.<BR> Results: Five of six iliac artery lesions were curved at the pre-procedural RDA evaluation. After the first series of DA, only two of six iliac lesions but all SFA lesions achieved the end point. Among the four other iliac lesions, three achieved the end point with one or two additional series of DA using the RDA system guidance to control the selective cuts of the residual plaques. One patient had a residual stenosis of 50% because the procedure could not be completed by balloon rupture of the DA catheter. In the patients with iliac stenoses, there was no final residual stenosis in one, and the range was from 20% to 25% in the four patients. The residual stenoses were located on the greater curvature side of the curved artery in three of these four patients.<BR> Conclusion: The RDA system is a valuable tool in aiding reduction of the residual stenoses during peripheral DA. Minimal stenoses often remain on the greater curvature side of the wall because the rigid and straight metallic capsule (cylindrical housing) of the Simpson DA catheter does not completely fit the curved wall. This phenomenon was thought to be a mechanical limitation of this device.
- 日本医科大学医学会の論文
日本医科大学医学会 | 論文
- わが国における腸チフスの疫学的考察--1973年〜1976年届出菌検出例を中心として
- 臨床および実験報告 二絨毛膜双胎妊娠における高年初産の検討
- 救急災害医学の確立と展望[含 略歴 研究業績] (定年退職教授記念講演会講演要旨)
- 臨床のために 関節リウマチの診断と治療
- TNFファミリーの制御による関節リウマチ治療の可能性 (特集 第15回公開「シンポジウム」(アレルギー・膠原病に対する新たな展開))