A New System for Measuring Gravity Flow Rate of Powder and Granule through Circular Orifice. Measurement of Flow Rate in Very Small Time Segment.:Measurement of Flow Rate in Very Small Time Segment
スポンサーリンク
概要
- 論文の詳細を見る
For studying the fluidity of powder and granule, the measurement of flow rate through an orifice is very crucial. However, until now we have not been able to measure the flow rate accurately. Formerly, flow rate was determined according to the quantity of flow over a 10-60 second time period. In this study, we have developed an accurate method for measuring flow rate over a very short time period (0.13 seconds). By this measurement apparatus, we can observe changes in flow rate behavior that was not possible in previous studies. From this study, a new flow behavior became clear and it was proved that the previous theory can be applied to a very short time period.
- 農業機械学会の論文
農業機械学会 | 論文
- 千切大根の乾燥特性 ―収縮を伴うみかけの減率乾燥―
- 水浸時の精白米の裂傷に関する研究
- 赤外線ガス分析計による籾・小麦の呼吸特性の測定
- 籾のマイクロ波乾燥に関する基礎的研究
- 氷蓄熱冷却式貯蔵庫による伊予柑の貯蔵とシステムの熱負荷特性の解析