The combustion of waste FRP with a fluidized bed furnace.
スポンサーリンク
概要
- 論文の詳細を見る
A large number of old FRP boats, that were constructed in the early days of the practical application of FRP, lasted for a prospective life span of more than 20 years and will have probably been retired from service in a few years. Therefore, the disposal of waste FRP materials by combustion with a fluidized bed furnace is investigated together with an investigation on the secondary influences of emission gas in the atmospheric environment. The results indicate that a uniformity of the temperature in the furnace is maintained without any occurrence of adhesion of melted glass contents to the furnace wall and that the plastic components of FRP are almost completely fired in the fluidized bed furnace with restricted concentrations of black smoke and offensive odor confined in the emission gas. A decrease in the furnace temperature to 700°C causes choking of the dust separator in the exhaust line of the furnace due to fibrous glass entrained in the emission gas.
- 一般社団法人 日本機械学会の論文
一般社団法人 日本機械学会 | 論文
- PREFACE
- Hybrid Vibration Suppression of Flexible Structures Using Piezoelectric Elements and Analog Circuits
- Application of Momentum Exchange Impact Dampers to Forging Machine
- アルミニウム繊維層を設置した流路の熱伝達と圧力損失特性
- 地震荷重下における配管のき裂進展評価手法の提案