Evaluation of the Surface Contamination Density with <SUP>51</SUP>Cr by Direct Measurement Method using a GM Survey-meter
スポンサーリンク
概要
- 論文の詳細を見る
It is difficult to detect a low level contamination with <SUP>51</SUP>Cr using a scintillation survey-meter because background counting rate of the survey-meter is high and emitted rate of λ-rays (0.320 MeV) from <SUP>51</SUP>Cr is less than 10%. We examined whether a surface contamination with <SUP>51</SUP>Cr can be detected directly with a GM survey-meter. As the result, the detection efficiency and detection limit of the GM survey-meter against the surface contamination were more than 0.6%(4π) and 4.6 13q/cm<SUP>2</SUP>, respectively. From measurement of transmittance of radiations from <SUP>51</SUP>Cr against poly (vinylidene chloride) seat, it became clear that the majority (about 98%) of detected radiations with the GM survey-meter is characteristic X-rays. These results show that the GM survey-meter can be used as a detector to check a surface contamination with <SUP>51</SUP>Cr in controlled area.