Clinical results and post operative radiological assessment of total knee replacement.
スポンサーリンク
概要
- 論文の詳細を見る
For the purpose of obtaining the most ideal and precise placement in future total knee prostheses, we evaluated the position of the devices used in such operations at our hospital by our own radiological scoring system. In a follow-up period of three years and nine months on 71 joint operations in 51 cases evaluated through radiography, 41 received scores of excellent (51%) ; 19, good (27%) ; 9, fair (12%) ; and 2, poor (3%) . The early clinical results of total knee arthroplasty were compared with these.<BR>The results showed that there were tendencies for cases with good clinical results to have good radiological scores and, to the contrary, for cases with poor results not to.<BR>In this short term study there was no significant positive correlation between good clinical results and a well-positioned prosthesis. But it seemed suggested that long-term clinical results would definitely be correlated with the positioning of the prosthesis.<BR>The comparison of the total condylar type and the kinematic type of total knee replacement showed that the kinematic type was better than the total condylar type in both clinical and radiological scores.
- 日本関節病学会の論文
日本関節病学会 | 論文
- 関節リウマチ患者における手術と機能回復
- 低出力超音波刺激(LIPUS)および線維芽細胞増殖因子(FGF-2)の骨形成促進作用におけるヒアルロン酸(HA)の影響
- 変形性関節症に対するグルコサミン・コンドロイチンの有用性 (第36回[日本関節病]学会寄稿)
- 人工膝関節再置換術の経験--脛骨結節骨切り術の適応と合併症について
- RA頚椎病変に対する上位頚椎後方除圧固定術の治療成績と問題点