Treatment of Thrombosed Prosthetic Valve for Duromedics Valve in the Atrioventricular Position.
スポンサーリンク
概要
- 論文の詳細を見る
Between March 1985 and May 1988 we performed valve replacement to 86 cases using 92 Duromedics prosthetic valves in the atrioventricular position. Long term results were obtained, we examined the problem (especially thrombosed valve). The cumulative follow-up was 313.6 patients-year (p-y). The 6-year actuarial survival rate including early mortality was 83.4±4.1%. The valve-related complications were as follows; peripheral embolism 3 cases (1.0%/p-y), thrombosed valve 7 cases (2.2%/p-y), hemorrhage and paravalvular leakage each 1 case (0.3%/p-y). All valve-related complications were 12 cases (3.8%/p-y). Reoperation for valve-related complications were 5 cases (1.6%/p-y), it was all to thrombosed prosthetic valve. Thrombosed valve were seen 7 cases (4 cases in mitral, 3 cases in tricuspid position). The event free rate of thrombosed valve was 89.1±4.0%. It was high incidence in tricuspid position. We concluded that it was necessary to be done early reoperation the time of fixed with one leaflet alone.