Temperature Dependence of the Thermal Conductivity of Core Samples from the Test Wells at Yakedake Geothermal Area
スポンサーリンク
概要
- 論文の詳細を見る
Hot Dry Rock technology requires a thorough knowledge of the variation of the thermal properties of rocks up to depth of the order of five kilometers. Temperature dependences of the thermal conductivity of 42 core samples from three test wells having 300 m depth at the field test site for the HDR technology in Yakedake geothermal area are presented in the temperature range 20-500°C. They are measured by a needle probe method. The thermal conductivity of the core sample exhibits θ<SUP>1</SUP>, θ<SUP>0</SUP> and θ<SUP>-1</SUP> dependences on temperature, θ, macroscopically. However, they are more complicatedly classified into θ<SUP>1</SUP>+θ<SUP>0</SUP>, θ<SUP>-1</SUP>+θ<SUP>0</SUP>and θ<SUP>-1</SUP>+θ<SUP>1</SUP> dependences on θ in addition to above the three dependences, microscopically. In situ thermal conductivities of the rocks and terrestrial conduction heat flows at depths 110, 200 and 300 m in one of the test wells, HY well, are estimated by the obtained data.