Investigation of pH Control Method to Avoid Silica Scaling in the Sumikawa Geothermal Field.
スポンサーリンク
概要
- 論文の詳細を見る
To avoid silica scaling, three different pH conditions (5.0, 6.5 and 7.3) were examined by passing Sumikawa geothermal fluids (SiO<SUB>2</SUB> concentration ; 775 mg/L) through columns (50 mmφ, 55 cm in length) packed with alumina beads (1 or 2 mmφ). The flow rate decreased from 5 to 2∼3 L/min with time (within 72 hours) in all pH conditions. Silica was found to deposit mainly around the top of the column (within 20 cm from the top), where Al concentration in the silica deposits increased with time. The total amount of silica deposited during experiments increased drastically with increasing amount of fluid after some induction periods where no significant amount of silica was deposited. In the most acidic condition (pH 5.0), silica deposition was also observed instead of an iron material such as SS400 was corroded. These results indicate that around pH 6.5 is a better condition to avoid silica scaling instead of a small amount of silica is still deposited for fluids with high SiO<SUB>2</SUB> concentration (>700 mg/L).
- 日本地熱学会の論文
日本地熱学会 | 論文
- 秋田県湯沢雄勝地域産流体包有物の研究 : 温度履歴と地熱流体の化学的性状
- 葛根田地熱地域における浅部貯留層の流体包有物のガス組成
- 低温溶液中のケイ酸の重合に及ぼす pH および金属陽イオンの影響について
- ダブルU字管型地中熱交換器の熱抽出特性