Discharge Capacity of Prefabricated Vertical Drain Confined in-clay
スポンサーリンク
概要
- 論文の詳細を見る
This paper reports the long-term discharge capacities of 5 types prefabricated vertical drains (PVDs) under clay confinement. The results indicate that under clay confinement, the discharge capacities significantly reduced with elapsed time. The possible reasons for the reduction are creep deformation of the filter of PVD, and clogging of drainage channels. Creep test results indicate that for the conditions considered, the creep deformation is limited, which implies that clogging is a main influencing factor. Test data showed that factors in favor of reducing clogging effect all resulted in an increase on long-term discharge capacity. Based on the test results, an empirical equation is proposed for estimating the long-term in-clay discharge capacity. It is recommended that in term of long-term discharge capacity, a PVD with a larger drainage area per channel and larger shape-factor of drainage channel may be selected. The shape factor is defined as the drainage area per channel divided by its periphery length.
- 国際ジオシンセティックス学会 日本支部の論文
国際ジオシンセティックス学会 日本支部 | 論文
- 二重壁構造を有する補強土壁の両面盛土への適用
- 二重壁構造をもつ垂直補強土擁壁の現場実験と数値解析
- 廃棄物処分場向け遮光性保護マットの屋外暴露挙動について
- 線状高分子混合処理土と遮水シートの境界面における遮水性の評価
- 補強土擁壁の地震時変位量計算手法の構築及び実被害事例への適用