Application of Lumped Parameter Model for Evaluating Pressure Interference Influences in Geothermal Reservoir Management
スポンサーリンク
概要
- 論文の詳細を見る
Three production wells of H-17, H-28, and H-29 discharged fluids from the reservoir formed along the Hatchobarufault. Pressure interferences among these wells were recognized by the change of discharge rate and geochemical monitoring data. The productivity of H-28 located between H-17 and H-29 declined due to the interferences, and the supply of steam to the power plant was often discontinued. Therefore a lumped parameter reservoir model for estimating hydraulic characteristics of reservoir and interferences from other production wells was developed and applied for analyzing Cl concentration and silica temperature monitored both in H-28 and 11-29.<BR>Analysis results indicated that discharges of wells H-17 and H-29 affected that of H-28. Pressure interference among wells H-17 and H-28 with H-29 was negligible small. Moreover it is presumed that an abrupt change of reservoir pressure is apt to occur in H-28 because the reservoir volume related to H-28 is about half in magnitude that of H-29. Accordingly the pressure interference of H-17 and H-29 resulted in appreciable pressure drop in H-28 reservoir. Thus analysis using the developed lumped parameter model can be used for quantitative evaluation of pressure interference influences in geothermal reservoir management.
- 日本地熱学会の論文
日本地熱学会 | 論文
- 秋田県湯沢雄勝地域産流体包有物の研究 : 温度履歴と地熱流体の化学的性状
- 葛根田地熱地域における浅部貯留層の流体包有物のガス組成
- 低温溶液中のケイ酸の重合に及ぼす pH および金属陽イオンの影響について
- ダブルU字管型地中熱交換器の熱抽出特性
- シングルU字管型地中熱交換器の熱抽出特性