Rapid High Resolution MR Neurography with a Diffusion-weighted Pre-pulse
スポンサーリンク
概要
- 論文の詳細を見る
Purpose: To introduce, optimize, and assess the feasibility of a new scheme to rapidly acquire high-resolution volumetric neurographic images using a three-dimensional turbo spin-echo sequence combined with a diffusion-weighted pre-pulse called improved motion-sensitized driven equilibrium (iMSDE): Diffusion-prepared MR Neurography (D-prep MRN). Methods: In order to optimize the signal suppression of blood vessels and muscle at D-prep MRN, coronal lumbosacral plexus images were acquired in five volunteers at 3T, and the following parameters were examined: iMSDE gradient-strength (b-value) of 0, 2 and 10 s/mm2 (with the aim to suppress blood vessels) and iMSDE preparation duration (iMSDEprep-time) of 18, 50 and 100 ms (with the aim to suppress muscle signal). Subsequently, the feasibility of the optimized D-prep MRN sequence in visualizing the brachial plexus, lumbosacral plexus, and cranial nerves was evaluated in 5 healthy volunteers. Results: A higher b-value of 10 s/mm2 was better in signal suppression of blood vessels, whereas an intermediate iMSDEprep-time of 50 ms provided the best compromise between suppression of muscle signal and minimization of signal loss of nerves. With these parameters, the normal nerve structures showed high signal intensity, while the blood vessels and muscles were effectively suppressed. The optimized D-prep MRN sequence clearly showed the three-dimensional trajectory of the brachial plexus, lumbosacral plexus, and cranial nerves. Conclusion: D-prep MRN was introduced and optimized, and clearly showed detailed anatomy of the brachial plexus, lumbosacral plexus, and cranial nerves. These results suggest that the D-prep MRN can be used for fast, high-resolution, volumetric imaging of the peripheral nervous system.
著者
-
Takahara Taro
Department Of Biomedical Engineering Tokai University School Of Engineering
-
Kwee Thomas
Department Of Radiology University Medical Center Utrecht
-
TAKAHARA Taro
Department of Biomedical Engineering, Tokai University School of Engineering
-
YONEYAMA Masami
Yaesu Clinic
-
NAKAMURA Masanobu
Yaesu Clinic
-
TABUCHI Takashi
Yaesu Clinic
関連論文
- Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) : Technical Improvement Using Free Breathing, STIR and High Resolution 3D Display
- Non-contrast Enhanced MR Venography Using 3D Fresh Blood Imaging (FBI): Initial Experience
- Utility of Cine MR Urography of the Urinary Tract and Comparison with Static MR Urography
- Diagnostic Magnetic Resonance-Urography in an Infant Girl with an Ectopic Ureter Associated with a Poorly Functioning Segment of a Duplicated Collecting System
- Practical Aspects of Assessing Tumors Using Clinical Diffusion-weighted Imaging in the Body
- Moderately T_2-weighted Images Obtained with the Single-Shot Fast Spin-Echo Technique : Differentiating between Malignant and Benign Urinary Obstructions
- Effective Performance of T_1-weighted FLAIR Imaging with BLADE in Pediatric Brains
- Diffusion-weighted Imaging with Relative Signal Intensity Statistical Thresholding for Delineating Prostate Cancer Tumors
- Rapid High Resolution MR Neurography with a Diffusion-weighted Pre-pulse