常時PMU計測値を用いた短絡電流推定手法とその実系統試験 (特集 平成24年電力・エネルギー部門大会)
スポンサーリンク
概要
- 論文の詳細を見る
This paper proposes estimation methods of short circuit current using phasor measurement unit (PMU) measurements (phasors). The methods follow the basic notion of representing the source side of a power system by an equivalent circuit with a voltage behind back impedance, and employ a set of voltage and current phasors measured at substations during the normal variation of loads in their estimation. In order to improve the estimation accuracy of the proposed methods, the concept of using the changes between the consecutive phasors is introduced. Furthermore, to make the methods applicable to the real world system, a reference phasor concept to remove the effects of system wide frequency variations and a filtering process to filter out the outlier phasors, are proposed and implemented. The validity and effectiveness of the proposed methods were checked and confirmed using experiments and field tests.
著者
-
小林 武則
(株)東芝 電力・社会システム技術開発センター
-
小俣 和也
(株)東芝 電力・社会システム技術開発センター
-
小林 武則
(株)東芝 電力流通システム事業部
-
Verma Suresh
中部電力(株)技術開発本部 電力技術研究所
-
中地 芳紀
中部電力(株) 流通本部 系統運用部
-
高林 芳樹
(株)東芝 電力流通システム事業部
-
和澤 良彦
中部電力(株)技術開発本部 電力技術研究所
-
小坂 葉子
(株)東芝 電力・社会システム技術開発センター