Novel glutamate biosensor was fabricated by coupling of a glutamate oxidase (GlOx) to a copper ion embedded polyion complex membrane composed of double-stranded DNA and polyallylamine (PAA), which prepared on a surface of the glassy carbon (GC) electrode. A hydrogen peroxide (H2O2) produced during the GlOx reaction was cathodically detected, based on an electrocatalytic activity of a DNA-Cu(II) complex for a reduction of H2O2. The cathodic current responses to L-glutamate obtained at −0.2 V (vs. Ag/AgCl) and at pH 6.0 linearly increased up to 100 µM with a detection limit of 1 µM (S/N=3). The sensitivity (slope of the linear region) was 0.80 nA/µM, and the response time was less than 20∼30 s. The sensor retained its response characteristics for at least five days by the storage in dry state at 4°C.
- 公益社団法人 電気化学会の論文
著者
-
Hasebe Yasushi
Department Of Applied Chemistry Faculty Of Engineering Saitama Institute Of Technology
-
KUSAKABE Hitoshi
Yamasa Corporation
-
HASEBE Yasushi
Department of Applied Chemistry, Faculty of Engineering, Saitama Institute of Technology
-
GU Tingting
Department of Materials Science and Technology, Graduate School of Engineering, Saitama Institute of Technology
関連論文
- EFFECTS OF VALPROIC ACID ON SPINAL REFLEXES AND [^3H]MUSCIMOL AND [^3H]DIAZEPAM BINDING IN BRAIN MEMBRANES IN RATS
- Structure-Activity Relationships of Phenylethylamine Analogs in Their Serotonergic Depressant Effects on the Spinal Monosynaptic Reflex in Rats
- Enhancement of Spinal Monosynaptic Reflexes with Phenylethylamine and Related Drugs through Descending Noradrenergic Neurons
- Chemically Amplified Flow-Injection Analysis of Polyphenolic Compounds using Immobilized-Tyrosinase Reactor and L-Ascorbic Acid, Based on Substrate Recycling
- Formation of aniline-bonded catechols in aqueous solution, and their electrochemical behaviors at carbon felt electrode
- Carbon Felt-based Bioelectrocatalytic Flow Detectors : Highly Sensitive Amperometric Determination of Hydrogen Peroxide Using Adsorbed Peroxidase and Thionine
- Carbon felt-based reagentless amperometric hydrogen peroxide biosensor usingco-immobilized toluidine blue O and horseradish peroxidase
- Production of D-Glutamate from L-Glutamate with Glutamate Racemase and L-Glutamate Oxidase
- Carbon-felt-based Bioelectrocatalytic Flow-detectors : Role of Ultrasound Irradiation during the Adsorption of Horseradish Peroxidase and Thionine for a Highly Sensitive Amperometric Determination of H_2O_2
- Carbon-felt-based Bioelectrocatalytic Flow-detectors : Optimization of the Adsorption Conditions of Horseradish Peroxidase and Thionine onto Carbon-felt for Highly Sensitive Amperometric Determination of H_2O_2
- Chemically amplified current responese of FAD-enzyme electrodes based on the intermediate regeneration induced by L-ascorbate
- アスコルビン酸による酵素中間体再生反応に基づくFAD-酵素固定化電極の化学増幅電流応答〔英文〕 (バイオエレクトロケミストリ-の新展開)
- _L-Ascorbate sensor with polypyrrole coated carbon felt membrane, electropolymerized in a cucumber juice solution
- Functional Conversion of Metallo-Proteins : Novel Ascorbate Oxidase Activity of Copper-Monoamino Oxidase Induced by Exogenous Ligands
- ヘモグロビン吸着カーボンフェルトによる酸素の生体触媒的電解還元と、アジ化物による阻害
- Glutamate Biosensor Using a DNA-Cu(II)/polyamine Membrane as a Novel Electrocataytic Layer for Cathodic Determination of Hydrogen Peroxide