Efficacy of Ventricular Capture Management in Patients with Single or Dual Chamber Pacemakers
スポンサーリンク
概要
- 論文の詳細を見る
<B>Introduction:</B> Medtronic Ventricular Capture Management (VCM) allows effective long-term management of the pacing output and thus, maximises battery longevity. The aim of this study is to determine the accuracy of the VCM and results were comparable with in-office manual threshold results (MTR). <B>Method:</B> Patients with bradyarrhythmia indications who received a Medtronic device with VCM were recruited. Clinical demographics were collected and analysed. The VCM data was analysed and compared with in-office MTR. VCM was turned on only 3 months after implantation. <B>Results:</B> There were 30 patients (13 male, 17 female) of mean age 71 years old. 13% received single chamber pacemaker. The mean duration of initial implantation was 2.5 years. 14 patients (46.7%) had identical VCM threshold results and in-office MTR. 15 patients (50%) had+0.25 V difference between VCM threshold results and in-office MTR. Only 1 patient (3.3%) was shown to have 0.5 V difference between VCM threshold results (1.125 V @ 0.4 ms) and in-office MTR (0.625 V @ 0.4 ms). <B>Conclusion:</B> VCM is considered to be accurate and comparable to in-office manual threshold tests at least 3 months after device implantation. VCM reliability will allow proper management of the pacing output by adjusting accordingly to the threshold obtained automatically.
著者
-
Teo Wee
Department Of Cardiology National Heart Centre
-
Ching Chi
Department of Cardiology, National Heart Centre Singapore
-
Liew Reginald
Department of Cardiology, National Heart Centre Singapore
-
Chong Daniel
Department of Cardiology, National Heart Centre Singapore
-
Tan Boon
Department of Cardiology, National Heart Centre Singapore
-
Chong Hui
Department of Cardiology, National Heart Centre Singapore
-
Liang Shufen
Department of Cardiology, National Heart Centre Singapore
-
Malik Amit
Department of Cardiology, National Heart Centre Singapore
関連論文
- Preparation and Characterization of Organic-Inorganic Layered Nanohybrid, Hydroxyl Double Salts (HDSs) : Isomer Separation via Preferential Intercalation into Layered Framework
- Atrial Fibrillation in Singapore and Malaysia : Current Trends and Future Prospects
- Fact-finding survey of antithrombotic treatment for prevention of cerebral and systemic thromboembolism in patients with non-valvular atrial fibrillation in 9 countries of the Asia-Pacific region
- Efficacy of Ventricular Capture Management in Patients with Single or Dual Chamber Pacemakers
- In a Multi-Ethnic Pacemaker Population, Are There Age Related, Gender or Ethnic Differences in Intracardiac Electrogram Amplitudes?
- In Secondary Prevention ICD Patients, Does the Initial Presenting VT Cycle Length Predict Subsequent Cycle Length of VT Episodes?
- Properties of phenytoin binding sites in the rat brain: Regional distribution and postnatal development.
- In a Multi-Ethnic Asian ICD Population, Are There Differences in Anti-Tachycardia Pacing Thresholds?