Multi-Channel Microwave Reflectometer with Fermi Antenna Receivers
スポンサーリンク
概要
- 論文の詳細を見る
We have evaluated a Fermi antenna newly designed in X band for use in a multichannel reflectometer. The advantages of the Fermi antenna are that it can be adopted as an array antenna owing to its planer shape and fabricated with a low cost due to its compactness and a light-weighted structure. The radiation-beam widths in the E- and H-plane are almost equal to each other and the side-lobe levels are low. Plasma behaviors in the HITOP device are measured by reflectometry using two Fermi antenna receivers. Time evolution of the cutoff layer and plasma rotation velocity measured by the reflectometer are in good agreement with an electrostatic probe measurement.
- 社団法人 プラズマ・核融合学会の論文
著者
-
Inutake Masaaki
Department Of Electrical Engineering Tohoku University
-
Ando Akira
Department Of Anatomy Tohoku University School Of Medicine
-
HATTORI Kunihiko
Department of Electrical Engineering, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
関連論文
- Increased Expression of Metalloproteinase-8 and -13 on Articular Cartilage in a Rat Immobilized Knee Model
- Intra-articular Injection of Hyaluronan Diminishes Loss of Chondrocytes in a Rat Immobilized-Knee Model
- タンデムミラ-GAMMA 10 によるプラズマ閉じ込め
- Measurement of End Loss Electrons and Ions from a Hot Ion Plasma in a Tandem Mirror
- Temperature Anisotropy Measurement Using Diamagnetic Loop Array
- Plasma Current Sustainment and Ramp-Up by Electron Cyclotron Waves in the WT-2 Tokamak
- Formation of High Energy Electron Tail during rf Plasma Current Start-Up in the WT-2 Tokamak
- Current Sustainment by lower Hybrid Waves in the WT-2 Tokamak
- Toroidal Plasma Current Start-Up and Sustainment by rf in the WT-2 Toroidal Device
- Pitch-Angle Measurement of Ions by the Use of a Small Faraday Cup
- Suppression of Alfven Ion Cyclotron Instability in a Mirror by End Plugging
- Macroscopic Stability Control Experiments with Phased Antennas in the GAMMA10 Tandem Mirror
- Excitation of the Alfven Ion Cyclotron Mode Solely by the Ion Pressure Distribution
- Axial Structures of the Alfven Ion Cyclotron Mode in the GAMMA10 Tandem Mirror
- Preliminary Experiment on Electron Beam Injection for Tokamak Current Drive
- Analysis of the Radial Profile of Ion Temperature in ICRF-Heated GAMMA10 Plasmas Including the Effects of Ion Finite Larmor Radius
- Study of Gas Recycling in the GAMMA 10 Tandem Mirror Based on Numerical Model Calculations
- Interchange Stability Criteria for Anisotropic Central-Cell Plasmas in the Tandem Mirror GAMMA 10
- Cross-Polarization Scattering from Electromagnetic Plasma Waves in Ion Cyclotron Range of Frequencies
- Low-Frequency Waves during GAMMA 10 End-Plate Biasing Using Microwave Reflectometry
- Effect of Resonant Electrons on Ion Temperature Gradient Mode in Anisotropic Plasma
- Study of Action of Unstable AIC Waves on Electrons in a Tandem Mirror Plasma from Measurement of End Loss Electrons
- Study of Action of Unstable AIC Waves on Electrons in a Tandem Mirror Plasma from Measurement of End Loss Electrons
- Effects of Alfven Ion Cyclotron Waves on End-Loss Electrons from the GAMMA 10 Tandem Mirror(Nuclear Science, Plasmas, and Electric Discharges)
- Observation of a Radial Current at a Plug/Barrier Cell in GAMMA10 : Fluids, Plasmas, and Electric Discharges
- Observation of a Flute Mode Excited in the Center Cell of the GAMMA 10 Tandem Mirror by Using Far-Infrared Laser Scattering
- Application of Millimeter-Wave Phase-Imaging Interferometry to the Tandem Mirror GAMMA 10
- Measurement of Ultrashort-Pulse Cross-Polarization Scattering in a Tandem Mirror : Nuclear Science, Plasmas, and Electric Discharges
- Density Fluctuations Associated with Electromagnetic Waves in Ion Cyclotron Range of Frequencies
- Pulsed Arc Electrohydraulic Discharges for Water Purification
- Distribution of Type A and B Synoviocytes in the Adhesive and Shortened Synovial Membrane during Immobilization of the Knee Joint in Rats
- A Patient with Focal Fibrocartilaginous Dysplasia in the Distal Femur and Review of the Literature
- Characteristics of Atmospheric-Pressure DC Glow Discharge in Pin-Plate Electrodes by Gas Flow Stabilization Method
- Density Fluctuations of Electromagnetic Plasma Waves in Ion Cyclotron Range of Frequencies
- Displacement Characteristics of Series-Type Bimorph Actuator under High Applied Voltage : Piezoelectrics
- Fast Guest Exchange of a 1:1 Zinc Porphyrin-Amine Host-Guest Complex via a Six-Coordinated Zinc Porphyrin
- Reversibility of Immobilization-Induced Articular Cartilage Degeneration after Remobilization in Rat Knee Joints
- Effects of the Reaction Pressure on the Growth of PbTiO_3 Thin Films by the Photo-Chemical Vapor Deposition Method
- On the Epithelial Lining of the Cleft between Pars Distalis and Pars Intermedia in teh Mouse Adenohypophysis
- 29aC09P Puffing gas flow modulation experiment in the GAMMA 10 tandem mirror
- Remobilization Does Not Restore Immobilization-Induced Adhesion of Capsule and Restricted Joint Motion in Rat Knee Joints
- A Multi-Reflection Type Visible-Laser Interferometer for High Density Plasma Measurements
- Multi-Channel Microwave Reflectometer with Fermi Antenna Receivers