Microanalysis of Lithium by Stable Isotope Dilution Method
スポンサーリンク
概要
- 論文の詳細を見る
The lithium contents of three kinds of the aluminium samples were determined by the method of stable isotope dilution. The results obtained are as follows: 99.9% purity aluminium:(5.5±0.3)×10<SUP>-9</SUP> g/g, 99.999% purity aluminium:(3.3±0.2)×10<SUP>-9</SUP> g/g, and zone melted aluminium:(1.7±0.2)×10<SUP>-8</SUP> g/g. The lithium contents in the purified waters and hydrochloric acids used for extraction of lithium from aluminium were also determined to be:(1.335±0.005)×10<SUP>-10</SUP> g/ml(water<SUP>a)</SUP>), (2.6±0.2)×10<SUP>-12</SUP> g/ml(water<SUP>b)</SUP>), (2.6±0.2)×10<SUP>-10</SUP> g/ml(hydrochloric acid<SUP>c)</SUP>)(5.4±0.4)×10<SUP>-11</SUP> g/ml(hydrochloric acid<SUP>d)</SUP>), and(2.83±0.05)×10<SUP>-12</SUP>g/ml(hydrochloric acid<SUP>e)</SUP>).
- 日本質量分析学会の論文
著者
-
OKADA SATOSHI
Radiation Center of Osaka Prefecture
-
TANIGUCHI SETSUO
Radiation Center of Osaka Prefecture
関連論文
- Ion-Molecule Reactions in Acetaldehyde and Methanol
- Microanalysis of Lithium by Stable Isotope Dilution Method
- The autoxidation of 2,3-dihydroxy-2-propenal (triose reductone). The effects of the pH on the rate constants.
- A mechanistic study of a gas-phase ion/molecule reaction between CH2NH2+ and CH4.
- Pulse radiolysis study of reaction of OH radicals with triose reductone.
- Oxidation of triose reductone by oxidizing inorganic radicals generated by pulse radiolysis.
- Ion-Molecule Reactions in Carbonyl Sulfide–Hydrocarbon Mixtures
- Proton Transfer Reactions in Oxygen-Containing Molecules and Ammonia Mixtures
- Pulse radiolysis of HgBr2 in aqueous solutions.