High performance micro-enzyme sensor using platinized microelectrode.
スポンサーリンク
概要
- 論文の詳細を見る
A unique micro-enzyme sensor for the determination of glucose has been prepared by incorporating glucose oxidase into the micropores of a platinized microelectrode. The electrode diameter is in the range from 10 μm to 200 μm. The detection limit is 5×10<SUP>−7</SUP> mol L<SUP>−1</SUP> for glucose, and an excellent linearity is obtained in the concentration range from 5×10<SUP>−7</SUP> to 10<SUP>−2</SUP> mol L<SUP>−1</SUP> in the case of micro-enzyme electrode whose diameter is larger than 50 μm. In the case of micro-enzyme electrode whose diameter is 10 μm, the detection limit for glucose is 10<SUP>−5</SUP> mol L<SUP>−1</SUP>, and the linearity is observed in the concentration range from 10<SUP>−5</SUP> to 5×10<SUP>−2</SUP> mol L<SUP>−1</SUP>. The sensor responds to every glucose sample of different concentration in 3 s or less, and the coefficients of variation for glucose (1 mM) determination were within 2%. The sensor output was stable over 4 weeks. This unique microfabrication approach to micro-enzyme electrodes enables the immobilization of intact enzyme molecules by a simple procedure.
- 公益社団法人 日本化学会の論文
著者
-
Aizawa Masuo
Department Of Bioengineering Faculty Of Bioscience And Biotechnology Tokyo Institute Of Technology
-
Ikariyama Yoshihito
Research Institute National Rehabilitation Center For The Disabled
-
Ushioda Hiroo
Central Research Laboratory, Sumitomo Cemment Co., Ltd.
-
Yamauchi Shigeru
Research Institute of National Rehabilitation Center
-
Yukiashi Tomoaki
Central Research Laboratory, Sumitomo Cemment Co., Ltd.
関連論文
- 電極上に自己集積したフラビン修飾α-ヘリックスペプチドの電極反応特性
- Post-Transcriptional Regulation of Immunomodulatory Cytokines Production in Human Skin Fibroblasts by Intense Mechanical Stresses
- バイオエレクトロニクスの進化と分子・細胞バイオ素子の研究開発
- 細胞の増殖,分化,遺伝子発現の電気刺激による制御
- ポリアニリン/酵素膜の電気化学合成およびコリンバイオセンサへの応用〔英文〕 (バイオエレクトロケミストリ-の新展開)
- Synthesis of Electroactive Protein Hybrid, Fec-BSA-Dig, and Its Application to a Novel Homogeneous Electrochemical Immunoassay
- Construction of a Bioreactor with Immobilized Yeast Cells for Production of a Low-phenylalanine Peptide Mixture as a Phenylketonuria Foodstuff(Food & Nutrition)
- 金・白金複合金属電極を用いたグルコースセンサの作製--電極表面における複数の機能性部位の導入
- Fabrication and Characterization of Gold-Platinum Black Electrode
- Design and Characterization of Polymer Matrix Anchored to Gold Thin Layer for the Effective Usage of Evanescent Field in SPR-based Immunosensor
- High performance micro-enzyme sensor using platinized microelectrode.
- Microbiosensing device for real time determination.