Active Vibration Control of AC Motors Using Linear Time Periodic Models
スポンサーリンク
概要
- 論文の詳細を見る
All rotating machines, such as electrical AC machines, suffer greatly from vibrations in their rotating parts. Vibrations occur at certain frequencies called critical frequencies that are always characteristic to the machine. Driving a machine at or near the critical frequencies cause two kinds of problems due to the vibrations. First, the air gap between the rotor and the stator must have greater safety margins, which decreases the efficiency of the motor. Otherwise, the motor would suffer a fatal damage from a rotating rotor hitting the stator. Secondly, wear of the structures is significantly increased due to vibrations which causes increased maintenance costs and decreased motor life-time. Active vibration control aims to suppress the vibrations at the critical frequencies by assistance of an additional actuator that is capable of exerting an external force to the rotor. This actuator is implemented with additional windings in the stator such that it has minimal effects on the normal operation of the motor. Active vibration control methods applied in electrical AC machines have previously mainly relied on linear time-invariant (LTI) models of the motor and correspondingly on traditional control methods such as LQ control and convergent control. These methods have produced successful results in active damping of vibrations and significantly decreased the vibrations at the critical frequency of the machine. In this paper, similar methods are studied in the case of a more accurate linear time periodic (LTP) system model of the electrical AC machine. Utilization of a more accurate model enables using more precise control and is therefore expected to give better controller performance. The performance of the developed periodic state feedback control method is compared to the performance given by a constant gain state feedback control. The developed control methods are tested by simulations with a model that is identified from the data measured from a 30kW squirrel-cage induction motor. It is revealed that the proposed control method works successfully but it gives only small improvement of performance in vibrations control. The reason for so moderate improvement of performance is supposed to be due to the small variations in the time-periodic parameters of the system model.
論文 | ランダム
- 南大東島における夏植えサトウキビの株出し不萌芽
- The role of catecholaminergic neurons in the hypothalamus and medullary visceral zone in response to restraint water-immersion stress in rats
- 16.ウィングタンクの破壊強度(その3) : 数値計算
- 特集1 シンポジウム:ホームヘルプ労働--職業としての確立をめざして
- 99.緊急セミナー 揺さぶられる介護保険--社会保障改革の論点を検証する (特集 介護保険法の施行)