磁器中の微量炭素定量と磁器の透光度
スポンサーリンク
概要
- 論文の詳細を見る
The carbon content in porcelain was determined by the application of the micromethod proposed by M. H. Kalina and T. L. Joseph (Blast Furnace and Steel Plant, 1939, 345-351) for carbon in steel. Specimens of porcelain were powdered to pass 130 mesh per inch and fused with red lead in a platinum boat in a current of oxygen. The carbon dioxide evolved was absorbed with barium hydroxide solution. Excess barium hydroxide was titrated back.As a measure of translucency, the extinction coefficient of porcelain thin plate was measured by a Hartmann microphotometer.A few examples of the measured results are shown in the following.Specimens were taken out from several parts of a working tunnel kiln. The water absorption and the carbon content of these specimens were measured. The results are shown in Fig. 3 (I&II). It was shown that the carbon content of specimens fired the range of 900° to 1000°C was about 0.03%, and it was reduced to about 0.01% before the beginning of the vitrification.
- 社団法人 日本セラミックス協会の論文
著者
関連論文
- 合成雲母結晶製造実験用炭素粒抵抗電気炉の設計と性能 : 合成雲母に関する研究所, 第XXXVI報
- 磁器中の微量炭素定量と磁器の透光度
- 磁器中の微量炭素定量と磁器の透光度
- 人工結晶
- 雲母合成用坩堝の研究(第3報)
- 雲母合成用坩堝の研究(第2報)(合成雲母に關する研究第XX報) : Al_2O_3-MgO-SiO_2系素地の燒成及び耐蝕試驗
- 磁器中の微量炭素定量と磁器の透光度
- 關白カオリン中のチタニウム鑛物について