Quantometric Analysis of Phosphorus in White Cart Iron
スポンサーリンク
概要
- 論文の詳細を見る
For the purpose of establishing routine quantometric analysis of phosphorus in white cast iron, a study has been made on various conditions of analytical techniques with the following results.<BR>(1) Excitation by a low voltage discharge (L: 360 teH, C: 30 pF, R: 50) gives satisfactory results.<BR>(2) Good results with reproducibility of below 4% variation are obtained by 10 sec.of pre-spark time and 20 sec.of constant integration time, the internal standard method being not used.<BR>(3) This procedure can be applied to the determination of phosphorus content in the range from 0.04 % to 0.6 %.<BR>(4) To raise the accuracy in this procedure, the following effects on the result should be taken into consideration:<BR>a) Effect of metallurgical history of the sample<BR>b) Effect of cracks on the sample surface.<BR>c) Effect of change in relative positions between exit slit and spectral lines by temperature variation.