Gamma-ray absorbed dose measurements in media with plural thermoluminescent dosimeters having different atomic numbers.
スポンサーリンク
概要
- 論文の詳細を見る
Corrective factors for thermoluminescent dosimeters to obtain the γ-ray dose in materials are examined systematically based on a general cavity ionization theory, and an experimental method; interpolation method, is presented for measuring the γ-ray absorbed dose in materials using thermoluminescent dosimeters with different atomic numbers. A characteristic feature of the method is to measure the γ-ray absorbed dose in materials without any γ-ray spectrum information. In order to examine the feasibility, the absorbed doses are measured in iron, lead and polyethylene media with a <SUP>60</SUP>Co γ-ray source, and compared with a transport cal-culations whose accuracy is already verified. It is shown that the γ-ray absorbed doses meas-ured using the present method agree with the calculated ones within ±5 to ±10%.
- 一般社団法人 日本原子力学会の論文
著者
-
TANAKA Shun-ichi
Japan Atomic Energy Research Institute
-
SASAMOTO Nobuo
Japan Atomic Energy Research Institute
関連論文
- Calculations of Effective Dose and Ambient Dose Equivalent Conversion Coefficients for High Energy Photons
- External Radiation Conversion Coefficients using Radiation Weighting Factor and Quality Factor for Neutron and Proton from 20 MeV to 10 GeV
- Validity of the Four-Parameter Empirical Formula in Approximating the Response Functions for Gamma-ray, Neutron, and Secondary Gamma-ray Skyshine Analyses
- Responses of LiF TLD in Different Media and Cavity Ionization Theory for Low Energy Photons below 200 keV
- Validity of the Four-Parameter Empirical Formula in Approximating the Response Functions for Gamma-ray, Neutron, and Secondary Gamma-ray Skyshine Analyses
- Analysis of neutron and secondary gamma-ray transport in air-over-ground geometry by PALLAS-2DCY-FC code.
- Monte Carlo calculations of source characteristics of FNS water cooled type tritium target.
- Calibration of Silicon PIN Photodiode for Measuring Intensity of 7-40 keV Photons.
- Experiments and calculations of 14MeV neutron streaming through multi-layered slit assembly.
- Gamma-ray energy spectrum calculations for plane perpendicular incident source including annihilation and bremsstrahlung photons.
- Gamma-ray absorbed dose measurements in media with plural thermoluminescent dosimeters having different atomic numbers.