Measurement of contact resistance and heat load test on graphite limiter.
スポンサーリンク
概要
- 論文の詳細を見る
A simple graphite limiter has been designed for high heat load in a tokamak device. The thermal contact conductance α<SUB>c</SUB> was measured as the function of contacting pressure p, because α<SUB>c</SUB>, is an important parameter for the graphite limiter design. Both experiments on small samples and full scale limiter assembly provided consistent data of α<SUB>c</SUB>=0.1 W/cm<SUP>2</SUP>•°C at p=1 kgf/cm<SUP>2</SUP> (0.1 MPa). This value is considered to be sufficiently large from the viewpoint of the limiter thermal design.<BR>Heat load test was performed on the simple graphite limiter by using electron beam. Two kinds of materials employed in the test were POCO graphite and SIC-6 graphite which has thermal expansion coefficient similar to that of SiC. The test results showed that both graphite materials had enough thermal shock resistance to the heat load q=500 W/cm<SUP>2</SUP>, t=320 s, and SiC coating on SIC-6 graphite had better behavior against thermal shock, comparing with TiC coating on POCO graphite.
- 一般社団法人 日本原子力学会の論文
著者
-
FUJIWARA Makoto
Mitsubishi Heavy Ind., Ltd.
-
NISHIKAWA Masana
Mitsubishi Atomic Power Ind., Inc.
-
UCHIKAWA Takashi
Mitsubishi Heavy Ind., Ltd.
-
IOKI Kimihiro
Mitsubishi Atomic Power Ind., Inc.
-
TATSUMI Ikuji
Mitsubishi Atomic Power Ind., Inc.