Experimental Study on Heat Removal Characteristics for Water Wall Type Passive Containment Cooling System.
スポンサーリンク
概要
- 論文の詳細を見る
To evaluate the heat removal capability of a water wall type cooling system, which is one passive containment cooling system (PCCS), the thermal hydraulic behavior in the suppression pool (S/P) and the outer pool (O/P. flat plate water wall) have been investigated experimentally. The following results were obtained. (1) A thermal stratification boundary, which separates the pools into the upper high temperature and lower low temperature regions, was formed just below the vent tube outlet. (2) Convection heat transfer characteristics in the S/P and O/P along the primary containment vessel (PCV) wall had no significant differences and were those of natural convection. Correlation of the natural convection heat transfer up to the Ra number of 2×10<SUP>14</SUP> was obtained. (3) Vertical variations of local condensation heat transfer coefficients under a noncondensable gas presence were within ±10% of the average value for the 4.7 m heat transfer length. An experimental correlation for the average condensation heat transfer coefficients was obtained as a function of steam and noncondensable gas mass ratio. (4) An analytical model to evaluate the system performance of the water wall type PCCS was verified. (5) A baffle plate concept to mitigate thermal stratification at the vent outlet and to enlarge the high temperature region in the S/P was considered as a means to improve heat release capability. Thermal hydraulics with a baffle plate were examined, and effectiveness of the baffle plate to improve the heat release capability was confirmed.
著者
-
FUJII Tadashi
Energy Research Laboratory, Hitachi Ltd.
-
KATAOKA Yoshiyuki
Energy Research Laboratory, Hitachi Ltd.
-
MURASE Michio
Energy Research Laboratory, Hitachi Ltd.
-
TOMINAGA Kenji
Hitachi Works, Hitachi Ltd.
関連論文
- Effect of a Divided Wetwell on Heat Removal Capability of the Water Wall Type Passive Containment Cooling System
- BWR Loss of Coolant Integral Tests with Two Bundle Loop, (II) : Effect of ECCS Activation Modes on Thermal-Hydraulic Characteristics
- Experimental Study on Heat Removal Characteristics for Water Wall Type Passive Containment Cooling System.
- Experimental Analysis on Mitigation of Thermal Stratification in the Suppression Pool of a Water Wall Type Passive Containment Cooling System.
- Investigation of measuring accuracy of automatic plugging indicator.
- Evaluation model of turbine meter for two-phase flow.
- Countercurrent gas-liquid flow in boiling channels.
- Countercurrent air-water flow in two vertical channels.
- Drift-flux parameters for upward gas flow in stagnant liquid.
- Performance analysis of mesh-packed cold traps.