Experimental Analysis on Mitigation of Thermal Stratification in the Suppression Pool of a Water Wall Type Passive Containment Cooling System.
スポンサーリンク
概要
- 論文の詳細を見る
A water wall type passive containment cooling system with an outer pool surrounding the suppression pool is one passive containment cooling system. In the system, a baffle plate in the suppression pool mitigates thermal stratification formed at the vent tube outlet level and enlarges the heat transfer area. The effectiveness of the baffle plate in mitigating thermal stratification was experimentally confirmed; the heat transferred to the outer pool increased about 50% due to a larger high temperature region and a longer effective heat transfer length. The experimental analysis was performed using a three-dimensional thermal-hydraulic analysis program. In the analysis, a laminar flow model and slip conditions on structural walls were used, and the calculated temperature profiles and natural circulation flow rates along the baffle plate agreed with measurements. The model was then judged as a valid and practical tool to evaluate global natural circulation and temperature distributions in a large pool. And it was analytically comfirmed that the thermal resistance of the PCV wall and the heat flux to the outer pool affected the performance of the baffle plate.
著者
-
FUJII Tadashi
Energy Research Laboratory, Hitachi Ltd.
-
KATAOKA Yoshiyuki
Energy Research Laboratory, Hitachi Ltd.
-
MURASE Michio
Energy Research Laboratory, Hitachi Ltd.
-
TAKAMORI Kazuhide
Energy Research Laboratory, Hitachi Ltd.
-
Takamori Kazuhide
Energy Research Laboratory Hitachi Ltd.
関連論文
- Effect of a Divided Wetwell on Heat Removal Capability of the Water Wall Type Passive Containment Cooling System
- Numerical Study of Two-Dimensional Structure in Critical Steam-Water Two-Phase Flow
- BWR Loss of Coolant Integral Tests with Two Bundle Loop, (II) : Effect of ECCS Activation Modes on Thermal-Hydraulic Characteristics
- Experimental Study on Heat Removal Characteristics for Water Wall Type Passive Containment Cooling System.
- Experimental Analysis on Mitigation of Thermal Stratification in the Suppression Pool of a Water Wall Type Passive Containment Cooling System.
- Investigation of measuring accuracy of automatic plugging indicator.
- Evaluation model of turbine meter for two-phase flow.
- Countercurrent gas-liquid flow in boiling channels.
- Countercurrent air-water flow in two vertical channels.
- Drift-flux parameters for upward gas flow in stagnant liquid.
- Performance analysis of mesh-packed cold traps.