Measurements of the Neutron Slowing Down Times in Finite Graphite Systems by the Resonance Filter Method
スポンサーリンク
概要
- 論文の詳細を見る
To shed further light on the neutron slowing down process, slowing down times were measured in graphite systems by the resonance filter method. The distribution of the slowing down time from 14 MeV to a few energy points from thermal equilibrium was obtained in the form of differences of time response between compensation-filter covered and resonance-filter covered BF<SUB>3</SUB> counters. From the time distributions thus determined were derived the most probable slowing down time t<SUB>max</SUB> and the average slowing down time <t>, which were compared with the theoretical values calculated with the use of various scattering kernels. The effects of finite medium and space dependence were also evaluated.<BR>The values of t<SUB>max</SUB> obtained were 9.5±0.5, 10.5±0.5, 20±1, 55±4, 71±4 and 101±8 μs for 5.2, 4.91, 1.46, 0.28, 0.2 and 0.11eV, respectively. Of these values, those over 1.46eV show good agreement with the theoretical values by 0°K free gas kernel, while those under 0.28eV agree well with the values by Williams' model, in which the effects of chemical binding and thermal vibration are considered.
- 一般社団法人 日本原子力学会の論文
著者
-
SUMITA Kenji
Faculty of Engineering, Osaka University
-
TAKAHASHI Akito
Faculty of Engineering, Osaka University
関連論文
- Measurement of Neutron Slowing Down Time in Graphite
- Measurements of the Neutron Slowing Down Times in Finite Graphite Systems by the Resonance Filter Method
- Theoretical Analysis on Time-Dependent Energy Spectra of Neutrons in a Small Graphite Assembly
- Development of in-reactor fuel behavior observation system.