集団聴力検査法の検討
スポンサーリンク
概要
- 論文の詳細を見る
There are two principal methods of screening test for loss of hearing in common use today.. One method is to use the group phonograph speech audiometer-usually for 40∼80 children at one time.The other method is to give each child an individual "sweep frequency test" with a pure tone audiometer.The advantage of the group phonograph speech test is that a large number of children can be screened in a relatively short time. This article presents the results of an experiment in comparing the performance of two group hearing tests.One thousand three hundred and sixty-eight elementary school children were tested. In the group phonograph speech test we used the Rion GA-1011 Group Audiometer produced by Kobayashi Institute of Physical Reseach and Western Electric 4CA Audiometer.They con- sist essentially of two parts connected together electrically;namely, an ordinary phonograph and 40-80 telphone receivers.The phonograph record was made by the Japan Central Commi- ttee of Eye and Ear Protection.The loudness of the spoken numerals on the phonograph record is graduated in such a manner that each succeeding series of numerals is reproduced at an intensity of 5 db less than the preceeding series.This is done in a range of 50db and then the voice starts again at the maximum intensity, repeating the process four times altogether with different combinations of numerals. In order to decide how much loss of hearing indicates any abnormality, 232 young women with normal hearing were tested with the group phonograph speech audiometer.The relation between the hearing loss and their frequencies was shown in Fig.4 and 5.As the results, a hearing loss of 12 (in right ear) and 9 (in left ear) sensation units or greater was used as a basis for determining those who could be accounted for by normal variations, On this basis, it will be seen that 125 out of 1368 pupils tested will be classed as having deficient hearing. In the individual "sweep frequency test" with a pure-tone audiometer, three frequencies, 1000, 2000 and 4000cps, were presented at fixed sensation levels of 25db.The performance:of, the group phonograph test and the sweep test has been compared on the same subjects, - all of whom has received the careful ordinary individual audiometer test.Frequencies presented in the test were the even octaves from 125 through 8000cps. In the following table the relation between the tests above mentioned has been shown.
- 社団法人 日本耳鼻咽喉科学会の論文
著者
関連論文
- 防音用耳栓の実験的研究
- 電気補聴器の適応に就いて
- 耳の保護のための防音具(防音用耳保護具)について
- 強い騒音による耳の障害 : 所謂騒音難聴
- 語音明瞭度検査用の語集に関する研究
- 人の音響性鼓室小筋反射が中耳伝音能率に及ぼす影響に関する一研究
- 聴覚疲労に関する研究
- 低調音障碍型を示す感音系難聽に關する研究 : 症例とその發生機序に關する一考察
- 語音明瞭度檢査用の語集に關する研究
- 新に製作せる語音明瞭度試驗用のロガトム音盤について
- 鐙骨筋の音響性反射収縮に関する実験的研究
- 幼児の乳様洞含気腔の発育
- 集団聴力検査の一方法 : 音盤の試作
- 顔面神経麻痺に随伴せる"Hyperacusis"について
- 鼓室小筋収縮が伝音器に及ぼす影響に関する実験的研究
- 所謂迷路震盪症の臨床的觀察
- 下音界に關する實驗的考察
- 頭部外傷後遺症における聴覚障害の臨床的考察
- 一骨導聴力測定装置の性能並びに測定條件に關する檢討
- 集団聴力検査法の検討
- 稀有な咽頭喉頭部の平滑筋腫の一治験例
- 語音明瞭度算出方法に関する研究