A new method of wettability measurement utilizing a small sample and its application to graphite or .ALPHA.-SiC and liquid Cu-Cr alloy systems.
スポンサーリンク
概要
- 論文の詳細を見る
The wettability of graphite and single crystal of α-SiC by liquid Cu-Cr alloy was investigated using the sessile drop method and the vertical plate method which was developed in this work.Main results are as follows;(1) The vertical plate method was proved to be applicable for the wetting system whose contact angle is acute.(2) The wettability of graphite by liquid Cu-Cr alloy dramatically changed at c.a. 0.3mass%Cr.(3) Electron probe microanalysis of the Cu-Cr alloy and graphite system revealed that Cr had concentrated at the interface.(4) Contact angles between liquid Cu-Cr alloys and single crystal of α-SiC were 10° and 10-20° at 0.23mass%Cr and 0.75mass%Cr, respectively.
- The Iron and Steel Institute of Japanの論文
著者
-
Ogino Kazumi
Department of Materials Science and Processing, Faculty of Engineering, Osaka University
-
Nogi Kiyoshi
Department of Materials Science and Processing, Faculty of Engineering, Osaka University
-
Osugi Yasuo
Osaka University