Effect of Operation Strategy and Control Structure on Multiple Steady-States of Heat Integrated Distillation Column (HIDiC)
スポンサーリンク
概要
- 論文の詳細を見る
Heat integrated distillation columns (HIDiCs) may have multiple steady-states, which may cause abrupt changes in process states. The present work presents two possible approaches to avoiding such multiplicity. The first approach is related to compressor operation strategies in the LV control structure; the strategy of constant compressor rotation speed can realize stable operation without multiple steady-states. The second approach is to adopt the DV or LB control structure. By employing one of these two structures, no multiplicity appears and stable operation of HIDiC can be realized. Herein, the usefulness of the proposed approaches is demonstrated though rigorous dynamic simulations.
著者
-
Wang Lin
Department Of Electrical Communications School Of Engineering Tohoku University
-
Manabu Kano
Department of Chemical Engineering, Kyoto University
-
Hasebe Shinj
Department of Chemical Engineering, Kyoto University
関連論文
- Effect of Operation Strategy and Control Structure on Multiple Steady-States of Heat Integrated Distillation Column (HIDiC)
- B-1-67 Diversity Performance of Modulated Scattering Antenna Array with Switched Reflector
- Experimental Study on MIMO Performance of Modulated Scattering Antenna Array in Indoor Environment
- Experimental study on MIMO performance of modulated scattering array antenna in indoor environment (アンテナ・伝播)
- Expression of GLUT-1 in psoriasis and the relationship between GLUT-1 upregulation induced by hypoxia and proliferation of keratinocyte growth
- Polymorphisms in the FOXP3 gene in Han Chinese psoriasis patients
- Extracellular signal-regulated kinase 1- and 2-mediated gastric mucosal injury and repair in gastric ischemia-reperfusion of rats