Protein and Synthesized Peptide pI Marker Analysis by Capillary Isoelectric Focusing Separation/Mass Spectrometry Using Sonic Spray Ionization (ノーベル化学賞記念特集号/TMS特集号(3))
スポンサーリンク
概要
- 論文の詳細を見る
Protein and synthesized-peptide pI marker analysis by using capillary isoelectric focusing separation/mass spectrometry (CIEF/MS) with a sonic spray ionization (SSI) interface, which has a buffer reservoir between the ion source and the separation capillary, has been demonstrated. Various proteins have often been used as pI markers for CIEF; however, they were unstable, so their pI could be changed from their expected ones. Therefore synthetic peptide pI markers are useful because of their higher stability and purity. However, the m/z of peptide pI markers are in the same range with those of the ions of polymers with a wide range of molecular weights due to ampholytes used for CIEF. As a result, detecting the protonated molecules of the peptide pI markers was difficult. In our work, we have optimized the scanning m/z range of a three-dimensional quadrupole (3DQ) ion-trap mass spectrometer to analyze of peptide pI markers and proteins, respectively, and to scan intensities of two ranges at the same time. Specifically, we separated the scanning range from 300 to 500 and from 700 to 1900. Using this method, carbonic anhydrase II, myoglobin, cytochrome-c, and four peptide pI markers were analyzed simultaneously by using CIEF/MS with an SSI interface, and these proteins were observed with reasonable pI values within the limit of the separation-power of this system.
- 日本質量分析学会の論文
- 2003-02-01
著者
-
HIRABAYASHI Atsumu
Central Research Laboratory, Hitachi Ltd.
-
Shimura Kiyohito
Faculty Of Pharmaceutical Sciences Teikyo University
-
HIRABAYASHI Yukiko
Advanced Research Laboratory, Hitachi, Ltd.
-
Hirabayashi Atsumu
Central Research Laboratory Hitachi Ltd.
-
Hirabayashi Yukiko
Advanced Research Laboratory Hitachi Ltd.
関連論文
- Sonic Spray Nebulizer for Inductively Coupled Plasma Atomic Emission Spectrometry
- キャピラリーアフィノフォレシスによるレクチンの糖に対する親和定数の決定
- Matrix Effect on the Analysis of Oligonucleotides by Using a Mass Spectrometer with a Sonic Spray Ionizatin Source
- Simple Miniaturized Amperometric Flow Cell for Monitoring Residual Chlorine in Tap Water
- Evaporation of Charged Droplets in Atmospheric Pressure Spray Mass Spectrometry
- Protein and Synthesized Peptide pI Marker Analysis by Capillary Isoelectric Focusing Separation/Mass Spectrometry Using Sonic Spray Ionization (ノーベル化学賞記念特集号/TMS特集号(3))
- Vibrational-Level Distribution in Electron-Impact Excitation of the N_2 C^3Π_u State:Its Disagreement with the Franck-Condon Approximation
- Multi-charged Oligonucleotide Ion Formation in Sonic Spray Ionization
- Capillary Isoelectric Focusing Separation Combined with Mass Spectrometry Using Sonic Spray Ionization for Protein Analysis
- Probe for Label-free Quantitative Analysis in Liquid Chromatography/Mass Spectrometry
- Determination of O-Glycosylation Heterogeneity Using a Mass-Spectrometric Method Retaining Sugar Modifications