Analysis on the Optimal Dispatching of Mixed-pump Stations and the Operating-mode Adaptability Based on Safety Water Supply
スポンサーリンク
概要
- 論文の詳細を見る
At present, constant speed pumps and variable speed pumps always run in parallel in pump stations of most water supply companies in China. Research on the frequency control characteristic for the mixed-pump station based on the two-stage optimal operation is performed. Firstly, the ratio of the variable speed pump is calculated inversely according to the outlet pressure of the pump station, and then the speed range can be determined dynamically, so that the variable speed pump can play the role of energy saving as far as possible in safe and rational running status. Secondly, the two-stage optimal operation model for mixed-pump stations of multi-source is established, which is of the operating-mode adaptability, and it is solved by the intelligent genetic algorithm. Furthermore, when the operation mode of multi-source pump stations is transformed, the optimal dispatching of water distribution system in corresponding operation mode can be realized through adjusting the variable parameters in the model. At last, the utility and superiority of the optimal operation method for mixed-pump stations of multiple resources is verified by means of the application in certain urban in China.
- Japan Society on Water Environmentの論文
著者
-
Li Ren
Maanshan Capital Water Co. Ltd., China.
-
Mou Lu
Department of Environmental and Municipal Engineering, Qingdao Technological University, China.
-
Shen Dong
Department of Environmental and Municipal Engineering, Qingdao Technological University, China.