Transition Edge Sensor-Energy Dispersive Spectrometer (TES-EDS) and Its Applications
スポンサーリンク
概要
- 論文の詳細を見る
The Transition Edge Sensor (TES)-Energy Dispersive Spectrometer (EDS) is an X-ray detector with high-energy resolution (12.8eV). The TES can be mounted to a scanning electron microscope (SEM). The TES-EDS is based on a cryogen-free dilution refrigerator. The high-energy resolution enables analysis of the distribution of various elements in samples under low acceleration voltage (typically under 5keV) by using K-lines of light elements and M lines of heavy elements. For example, the energy of the arsenic L line differs from the magnesium K line by 28eV. When used to analyze the spore of the Pteris vittata L plant, the TES-EDS clearly reveals a different distribution of As and Mg in the micro region of the plant. The TES-EDS with SEM yields detailed information about the distribution of multi-elements in a sample.
著者
-
TANAKA Keiichi
SII NanoTechnology Inc.
-
ODAWARA Akikazu
SII NanoTechnology Inc.
-
NAGATA Atsushi
SII NanoTechnology Inc.
-
BABA Yukari
SII Nano Technology Inc.
-
NAKAYAMA Satoshi
SII Nano Technology Inc.
-
AIDA Shigenori
Seiko Instruments Inc.
-
MOROOKA Toshimitsu
Seiko Instruments Inc.
-
HOMMA Yoshikazu
Tokyo University of Science
-
NAKAI Izumi
Tokyo University of Science
-
CHINONE Kazuo
SII Nano Technology Inc.
関連論文
- Development of a TES Microcalorimeter for Spectroscopic Measurement of LX-rays Emitted by Transuranium Elements
- Transition Edge Sensor-Energy Dispersive Spectrometer (TES-EDS) and Its Applications
- MICROCALORIMETER ENERGY-DISPERSIVE X-RAY SPECTROMETRY OF CLAY MINERALS BY TRANSMISSION ELECTRON MICROSCOPE
- Transition Edge Sensor-Energy Dispersive Spectrometer (TES-EDS) and Its Applications
- X-ray Microanalysis of Biological Samples by High-resolution Energy Dispersive Microcalorimeter Spectrometer Using a Low-voltage Scanning Electron Microscope
- REIDAC : A Software Package for Retrospective Dose Assessment in Internal Contamination with Radionuclides
- Frequency Domain Multiplexing of TES Signals by Magnetic Field Summation( Superconducting High-frequency Devices)
- Development of Integrated Direct Current Superconducting Quantum Interference Device Gradiometer for Nondestructive Evaluation
- Nondestructive Magnetic Detection of Plasticized Area Using Superconducting Quantum Interference Device
- Suppression of Washer Resonance of DC Superconducting Quantum Interference Device by Using New Washer with Additional Slit
- Relaxation Oscillator Using Nb/AlO_x/Al/Nb Josephson Junctions Measured with DC Superconducting Quantum Interference Devices
- Observation of Superconducting Device Using Magnetic Imaging System with a Micro-DC Superconducting Quantum Interference Device Magnetometer
- 1 pA/$\sqrt{\text{Hz}}$ Amplifier Using Superconducting Quantum Interference Device Array
- Spectral Analysis of Nanomaterials using a Transition-Edge Sensor Microcalorimeter Mounted on a Field-Emission Scanning Electron Microscope
- Observations of Single Magnetic Domain Wall in Nanomagnet by Magnetic Force Microscopy
- Design, Fabrication and Evaluation of a Four-Josephson-Junction Superconducting Quantum Interference Device with Two Superconducting Loops
- Characteristics of Flux Noise in Long Superconducting Quantum Interference Device Array
- Array of Superconducting Quantum Interference Devices with Multiturn Input Coil