Glow Discharge Characteristics in Relation to Anode Size in Inertial Electrostatic Confinement Fusion
スポンサーリンク
概要
- 論文の詳細を見る
An Inertial Electrostatic Confinement Fusion device is a very simple and safe neutron source that uses a glow discharge for deuterium-deuterium fusion. The discharge characteristics of the device were studied experimentally. The relationship between gas pressure and applied voltage was examined by light changes of the devices anode size. The gas pressure ranges in which the device was able to function effectively were differed. In the case of a larger anode (300 mm in diameter), the glow discharge occurred even under a relatively low pressure of 0.7 Pa and was very stable during a long period of neutron production. The characteristics of the gas pressure-neutron yield of different size anodes were also studied experimentally. At lower gas pressure, a greater neutron yield was obtained by a larger anode.
- 日本真空協会の論文
著者
-
OHNISHI Masami
Department of Pathology, Gifu University School of Medicine
-
OSAWA Hodaka
Department of Electrical Engineering and Computer Science, Kansai University
-
YOSHIMURA Shigehisa
Department of Electrical Engineering and Computer Science, Faculty of Engineering, Kansai University
-
TABATA Takehiro
Department of Electrical Engineering and Computer Science, Faculty of Engineering, Kansai University
-
OHNISHI Masami
Department of Electrical Engineering and Computer Science, Faculty of Engineering, Kansai University
-
Ohnishi Masami
Department of Electrical and Electronic Engineering, Faculty of Engineering Science, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680, Japan
-
OSAWA Hodaka
Department of Electrical Engineering and Computer Science, Faculty of Engineering, Kansai University
関連論文
- Suppressive Effects of S-Methyl Methanethiosulfonate on Promotion Stage of Diethylnitrosamine-initiated and Phenobarbital-promoted Hepatocarcinogenesis Model
- Inhibitory Effect of Chlorophyllin on Diethylnitrosamine and Phenobarbital-induced Hepatocarcinogenesis in Male F344 Rats
- LACK OF INHIBITORY EFFECT OF BENZYL ISOTHIOCYANATE ON 2-AMINO-1-METHYL-6-PHENYLIMIDAZO [4,5-b]PYRIDINE (PhIP)-INDUCED MAMMARY CARCINOGENESIS IN RATS
- Chemopreventive Effects of Taurine on Diethylnitrosamine and Phenobarbitalinduced Hepatocarcinogenesis in Male F344 Rats
- Shape of Electrodes for High Performance of Inertial Electrostatic Confinement Fusion
- Glow Discharge Characteristics in Relation to Anode Size in Inertial Electrostatic Confinement Fusion
- An Extreme Ultraviolet Source for Photolithographic Applications Based on Rotamak Discharge