Calculation of Radiated Emissions from Power Line with Four Port Network Theory
スポンサーリンク
概要
- 論文の詳細を見る
We measured the degree of unbalance to ground and the leaked electric field from a power line in the high frequency band, to obtain its radiation emission characteristics. We also constructed a calculation model for the power line and compared the results from this with measured values. It was constructed using four port network theory, which has the circuit constant as the chain matrix of the distributed constant on a transmission line. The structural unbalance of a power line was imitated by adjusting the additive distributed constant of a power line so that the calculated and measured values agreed with each other for Transverse Conversion Transfer Loss (TCTL) in the no grounding model. In calculating the leaked electric field, we assumed the power line was a conductor flowing common mode current, and calculated the leaked electric field by integrating radiated emissions from the common mode current in each minute section at the observation point. The calculated value for TCTL was mostly in agreement with the measured value confirming the validity of the calculation methods for TCTL. The leaked electric field increased about 20dB by grounding one wire on the line. The calculated value for the leaked electric field with no grounding almost agreed with the measured one. In near and far grounding, the calculated value almost agreed with the one measured.
- 社団法人 電気学会の論文
著者
-
WATANABE Yosuke
Department of Neurosurgery, Hiroshima City Asa Hospital
-
Watanabe Yosuke
Department Of Mathematical Sciences College Of Engineering Osaka Prefecture University
-
Shiozawa Hirotaka
Department of Electronics and Communication Engineering, Musashi Institute of Technology
-
Tokuda Masamitsu
Department of Electronics and Communication Engineering, Musashi Institute of Technology
-
Watanabe Yosuke
Department Of Internal Medicine Ii University Of Yamanashi Faculty Of Medicine
関連論文
- Analysis of Risk Factors for Infection in Coplacement of Percutaneous Endoscopic Gastrostomy and Ventriculoperitoneal Shunt
- Internal Carotid Artery Occlusion Following Correction of Atypical Aortic Coarctation : Case Report
- Metastatic Leiomyosarcoma of the Brain Manifesting as Multiple Hemorrhages : Case Report
- Periodic Wave Solutions as Imbricate Series of Rational Growing Modes:Solutions to the Boussinesq Equation
- Dissecting Basilar Artery Aneurysm Growing During Long-term Follow Up
- A Ruptured Distal Posterior Inferior Cerebellar Aneurysm Our Case and Review of the Literature
- Calculation of Radiated Emissions from Power Line with Four Port Network Theory
- Periodic Soliton Resonance : Solutions to the Davey-Stewartson I Equation
- Resonant Interactions of Y-Periodic Soliton with Line Soliton and Algebraic Soliton:Solitons to the Davey-Stewartson I Equation
- Effect of Average Stress in Films on Uniaxial Magnetic Anisotropy in Electrodeposited Nickel-Iron Thin Films
- On Unstable Modes of the Inviscid Kolmogorov Flow
- Early Improvement in Carotid Plaque Echogenicity by Acarbose in Patients With Acute Coronary Syndromes
- Mobile Intrinsic Localized Modes of a Spatially Periodic and Articulated Structure
- Echolucency of Carotid Plaque Is Useful for Assessment of Residual Cardiovascular Risk in Patients With Chronic Coronary Artery Disease Who Achieve LDL-C Goals on Statin Therapy
- Contrast-Enhanced Ultrasound Imaging of Carotid Plaque Neovascularization Is Useful for Identifying High-Risk Patients With Coronary Artery Disease
- Contrast-Enhanced Ultrasound Imaging of Carotid Plaque Neovascularization Is Useful for Identifying High-Risk Patients With Coronary Artery Disease