Design of a Dummy Load for the 2 MW HF Transmitter
スポンサーリンク
概要
- 論文の詳細を見る
A 2 MW transmitter with a frequency ranging from 30 to 60 MHz is used for the KSTAR ICRF heating source and it is necessary to equip it with a dummy load which has a low VSWR above the second or third harmonic frequency for testing the 2 MW transmitter. The resistive film type is well known as a non-inductive dummy load, however it cant be used above 300 kW because of problem at the surface adhesion between the ceramic substrate and the resistive film or sputtered carbon which imposes a limit on the power density of the film resistor. So, above 1 MW the most promising candidate is the soda water dummy load where the soda water plays a role in both the rf power absorbing medium and the cooling water. In this work, the electrical and mechanical design requirements of the 2 MW soda dummy load are introduced and RF characteristics are discussed using a lumped circuit model and a numerical analysis.
- 社団法人 電気学会の論文
著者
-
KWAK Jong-Gu
Korea Atomic Energy Research Institute
-
Wang Song-Jong
Korea Atomic Energy Research Institute
-
Yoon Jae-Sung
Korea Atomic Energy Research Institute
-
Hong Bong-Guen
Korea Atomic Energy Research Institute
関連論文
- Thirty-Minute Plasma Sustainment by ICRF, EC and NBI Heating in the Large Helical Device
- Design of a Dummy Load for the 2 MW HF Transmitter