Seismic Behavior of 200MPa Ultra-High-Strength Steel-Fiber Reinforced Concrete Columns under Varying Axial Load
スポンサーリンク
概要
- 論文の詳細を見る
Cyclic loading tests were carried out on ultra-high strength RC columns under high axial load conditions. Effective concrete strength of 200 MPa with high-strength steel fibers (SF) was used. The investigated parameters were: 1) volumetric ratio of steel fiber, 2) lateral reinforcement ratio, and 3) axial loading type. The main characteristics of the tested columns (maximum strength, deformation capacity and equivalent viscous damping factor) are presented and the influence of various parameters is discussed. The test results revealed the advantage of using SF in terms of strength and damage control. The maximum strength of the tested columns using SF, assessed using a number of different formulas, proved to be on the safe side. On the other hand, in the case of columns in which SF was not used, the estimated maximum strength was found to be larger than the tested value, except when using NZS3101 equation. This difference is probably due to early spalling off of the cover concrete.
- 公益社団法人 日本コンクリート工学会の論文
公益社団法人 日本コンクリート工学会 | 論文
- セメントの水和反応と硬化組織
- 城郭の石垣
- 鉄筋コンクリート研究小史
- 構成要素論から見たセメント工学
- Experimental Study on Bond-Strengthening Hooks for RC Beams