Ultrasonic Measurement of Bone Density and Young's Modulus (Study on measuring accuracy):(Study on measuring accuracy)
スポンサーリンク
概要
- 論文の詳細を見る
This study was performed as a part of the research on the ultrasonic measurement of bone porosity, bone density, and Young's modulus. It was found that the bone porosity estimated by Biot's theory agrees within 5% of the actual porosity. The bone's structure factor involved in the Biot's theory was determined experimentally to have a value of 2. It was also found that the use of the propagation velocity of the fast wave is more advantageous than using the slow wave in estimating bone porosity. The estimated bone density obtained by the use of Biot's theory is within ±5% of the measured value obtained by the use of Archimedes' principle. Bone density as well as Young's modulus can be estimated precisely by using the proposed ultrasonic wave method.
- 一般社団法人 日本機械学会の論文
著者
-
SHIBATA Hiroshi
Toyama National college of Maritime Technology
-
DING Bailin
Dept. of Mechanical Engineering, University of Toyama
-
ISHIHARA Sotomi
Dept. of Mechanical Engineering, University of Toyama
-
OTA Miki
Dept. of Mechanical Engineering, University of Toyama
-
GOSHIMA Takahito
Dept. of Mechanical Engineering, University of Toyama
-
TAKAZAWA Takeshi