Blood Viscometer with Vacuum Glass Suction Tube and Needle
スポンサーリンク
概要
- 論文の詳細を見る
A new type of viscometer for measuring human blood viscosity is made by using a vacuum glass tube and a capillary needle. This new viscometer needs a volume of only about 5 × 10–6–8 × 10–6 m3 of blood. Simple handling, quick measurement and accurate results in a wide shear rate range are its superior features. Additionally, the whole measuring set with the viscometer is easy to use and to carry, and it is not expensive.By using various standard-viscosity Newtonian liquids, it is confirmed experimentally that this viscometer is sufficiently accurate in the range of less than about 10–2 Pa·s. The viscosity of fresh human blood collected in a hospital is measured by the new viscometer and it is confirmed that the viscosity value obtained is reasonable by comparing it with that by a traditional measuring method. Further, it is shown that the new viscometer can measure the viscosities of other liquids which have complex properties.
- 社団法人 化学工学会の論文
著者
-
Ookawara S
Tokyo Inst. Technol. Tokyo Jpn
-
Ogawa Kohei
Tokyo Institute of Technology
-
Ookawara Shinichi
Tokyo Institute of Technology
-
Ito Shiro
Tokyo Institute of Technology
-
Taniguchi Koichi
Tokyo Medical and Dental University
-
Doi Mayumi
Tokyo Medical and Dental University
関連論文
- Flow Properties of Newtonian and Non-Newtonian Fluid Downstream of Stenosis
- Blood Viscometer with Vacuum Glass Suction Tube and Needle
- NON-NEWTONIAN FLOW CHARACTERISTICS OF BLOOD IN THE SHEAR RATE RANGE OF 100 - 10,000 s^
- -P44-RELATION AMONG CORONARY REPERFUSION, TRANSIENT QT PROLONGATION AND TECHNETIUM-99M PYROPHOSPHATE SCINTIGRAPHIC FINDINGS IN ACUTE STAGE OF MYOCARDIAL INFARCTION : RI : FREE COMMUNICATIONS(III) : PROCEEDINGS OF THE 53th ANNUAL SCIENTIFIC MEETING OF THE
- ASSESSMENT OF VENTRICULAR PREMATURE COMPLEXES IN PATIENTS UNDER MAINTENANCE HEMODIALYSIS BY SERIAL HOLTER RECORDINGS : Vasodilators, Hemodialysis : FREE COMMUNICATIONS (VI) : PROCEEDINGS OF THE 49th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SO
- A New Graphical Method for Calculation of Mass Transfer Time in a Deep Bubble Bed
- The Effect of Superficial Gas Velocity and Aerated Liquid Height on the Spatial Distribution of Local Liquid-Phase Axial Dispersion Coefficients in a Bubble Column
- Time-Dependent Mixing Behaviors in Lower and Upper Zones of Bubble Column
- A Fundamental Approach to Bubble Column Scale-Up Based on Quality of Mixedness
- Drop Size Distribution in Liquid-Liquid Mixing
- EVALUATION OF COMMON SCALING-UP RULES FOR A STIRRED VESSEL FROM THE VIEWPOINT OF ENERGY SPECTRUM FUNCTION
- RELATIONSHIP BETWEEN ANAEROBIC THRESHOLD (AT) AND CARDIAC FUNCTION DURING EXERCISE BEFORE AND AFTER ISDN : Exercise Test, Rehabilitation : 53 Annual Scientific Meeting, Japanese Circulation Society
- Mixing Spectrum of an Impeller Based on Whole Mixing Capacity
- Preface to the Special Issue for IWPI 2010
- A New Evaluation Index of Mixing State of a Local Region in a Vessel in Case of Multi-Component Mixing
- A method of scaling up equipment from the viewpoint of energy spectrum function.