LOCAL HEAT TRANSFER IN A STIRRED VESSEL WITH AND WITHOUT AERATION
スポンサーリンク
概要
- 論文の詳細を見る
A positive temperature coefficient thermister is devised as a thermal probe to determine local heat transfer coefficients in a stirred vessel with a standard Rushton turbine impeller. The effects of aeration and flow patterns on the value of local heat transfer coefficients are discussed. Under most operating conditions, the highest flux is found at the impeller discharge region and the front side of the baffle plates. The mean Nusselt number for jacket and baffle type heat exchange elements is presented in terms of the modified Reynolds number and the other dimensionless groups, as the results of the integration of the determined values of local heat transfer coefficients.
- 1995-12-01
著者
-
Hsu Wei
Department Of Chemical Engineering National Taiwan University Taipei
-
Wei Ming
Department Of Chemical Engineering National Taiwan University Taipei
-
CHIH Mingl
Department of Chemical Engineering, National Taiwan University Taipei
-
Chih Mingl
Department Of Chemical Engineering National Taiwan University Taipei
関連論文
- Study of Zinc-Delta-Doped Strained Quantum Well InGaAs/GaAs p-Channel Heterostructure Field-Effect Transistors
- LOCAL HEAT TRANSFER IN A STIRRED VESSEL WITH AND WITHOUT AERATION
- Effect of Back Mold Grooves on Improving Uniformity in Nanoimprint Lithography