新潟県内の環境水中クロムのイオン交換分離/誘導結合プラズマ発光分析法による形態分析(<特集>若手研究者の初論文特集)
スポンサーリンク
概要
- 論文の詳細を見る
A simple and an efficient preconcentration method for the separate determination of each species of chromium {i.e., Cr(III) and Cr(VI)} in environmental water samples has been investigated, followed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). This method is based on the following ion-exchange method. Cr(III) was adsorbed on cation-exchange resin, and Cr(VI) on anion-exchange resin. The retained Cr(III) and Cr(VI) were quantitatively eluted with 2 mol dm^<-3> hydrochloric acid (HCl) and 2 mol dm^<-3> potassium chloride (KCl), respectively. The preconcentration factor was 100 for Cr(III) and 300 for Cr(VI) in this work, and the detection limits were 0.03μg dm^<-3> in Cr(III) and 0.01μg dm^<-3> in Cr(VI). The method has been applied to environmental water samples from Niigata Prefecture. The recoveries of Cr(III) and Cr(VI) in environmental water samples were all 94〜98%, and the effect of interference from the coexistence ion was not detected. Therefore, the above-mentioned method is applicable to environmental water samples.
- 日本分析化学会の論文
- 2004-09-00
日本分析化学会 | 論文
- 大気中の粒子状物質の分析
- 機器分析法の基礎知識--X線回折分析法
- 大気粉じんの状態分析
- 化学的アプローチによるナノ領域の操作 : 固体表面における原子, 分子の構造制御集積による機能性物質相の創成
- 加速器質量分析法