The Required Compressive Strength and Prehardening Time to Prevent Damage to High Flowing Concrete from Frost Damage at Early Ages
スポンサーリンク
概要
- 論文の詳細を見る
This investigation was undertaken to develop data on the early frost resistance of high flowing concrete made either with various type of mineral fine powders or viscosity agents. From the results of this investigation it was found that the test cylinders cast from air entrained concrete (ie., air>3.5%)which cured up to 23°D.D prior to freezing, performed with satisfactory resistance to early freezing and thawing cycles. However the 28 days strength ratio of all AE specimens were above 100%. This study recommends early continuous protection until AE high flowing concrete has attained compressive strength of 70 to 80 kg/cm^2.
- 日本コンクリート工学会の論文
- 1995-00-00
日本コンクリート工学会 | 論文
- モルタル梁のコンテスト形式による学生実験の改善と教育効果
- ロシアサハリン2プロジェクト--スラグ高配合高炉セメントを用いた寒冷地におけるコンクリート工事 (特集 海外工事への新たなる挑戦) -- (海外工事の事例)
- 中東の厳しい環境下におけるコンクリート事情について--カタール国:新ドーハ国際空港建設工事 (特集 海外工事への新たなる挑戦) -- (コンクリートにかかわる海外事情・情勢)
- ドイツおよび韓国における建設産業の国際展開支援策 (特集 海外工事への新たなる挑戦) -- (国際展開に向けた人材育成と支援事例)
- 工事記録 海水環境にある排水機場の劣化調査とリニューアル工事