Effective lateral resistance of combined timber joints with nails and bolts
スポンサーリンク
概要
- 論文の詳細を見る
An experimental study on combined steel-to-timber joints with nails and bolts is conducted in this study. Principal results are as follows: The initial stiffness and effective allowable resistance of combined joints depend obviously on clearances in predrilled bolt-holes. The combined joints with nails and bolts have high potential of energy capacity to resist strong earthquake forces. There are upper limits of clearances in predrilled bolt-holes that allow advantages of considering the synthetic resistance of combined joints in practical structural design. Combining the joint components with appropriate design will give higher performance against strong earthquakes increasing the safety margin and energy capacity until the failure. The combined joints should be designed under the restrictions of particular specifications in closed design systems because the advantages of combining the joint components are influenced obviously by various actual conditions, which is too difficult to consider in detail in open design systems.
著者
関連論文
- Effect of Member Thickness and Nail Length Projecting from Main Member on Shear Performance of Single Shear Nailed Joints
- Evaluation of drag coefficients of poplar-tree crowns by a field test method
- Effect of decay on shear performance of dowel-type timber joints
- Bending resistance of repaired column members and shear resistance of opening frames with repaired columns of conventional Japanese wooden houses
- Nondestructive measurement of cross-sectional shape of a tree trunk
- Effective lateral resistance of combined timber joints with nails and bolts