Intraoperative evaluation of anteroposterior and rotational stabilities in anterior cruciate ligament reconstruction: lower femoral tunnel placed single-bundle versus double-bundle reconstruction
スポンサーリンク
概要
- 論文の詳細を見る
Twenty-six patients with anteroposterior (AP) laxity of the knee, associated with torn anterior cruciate ligament (ACL), were prospectively randomized for arthroscopic lower femoral tunnel placed single- or double-bundle reconstruction using hamstring tendons. We evaluated AP and rotational stabilities under regular loads (a 100-N anterior load and a 1.5-N m external–internal load) before and after ACL reconstruction, comparing single- and double-bundle reconstruction with our original device for applying quantitative tibial rotation and the navigation system intraoperatively. No significant differences were found between the two groups in AP displacement and total range of tibial rotation at 30° and 60° of knee flexion. We found that a lower femoral tunnel placed single-bundle reconstruction reproduced AP and rotational stability as well as double-bundle reconstruction after reconstruction intraoperatively.