Single-Detector CTを用いた腹部骨盤CTにおける造影剤低容量化の試み : イオヘキソール300(オムニパーク300,100mlシリンジ製剤)とイオベルソール320(オプチレイ320,75mlシリンジ製剤)を用いて
スポンサーリンク
概要
- 論文の詳細を見る
Purpose : The steadily elevating cost of the contrast-enhanced CT has been a problem in last decade. One approach to curtail the cost is to reduce the amount of contrast media (CM). The purpose of this study was to examine the possibility of reducing the volume of CM in single-detector CT (SDCT) without compromising diagnostic ability. Materials and Methods : One hundred ml of Iohexol 300 and 75 ml of Ioversol 320 were compared in a prospective CT study about their imaging quality. One hundred patients were randomly divided into two parallel groups (A and B). The former agent was used for group A and the latter for B. CT attenuations of the aorta, central vein, spleen and kidney were measured and each imaging quality was reviewed by three radiologists. Results : CT attenuations and the imaging quality were significantly superior (p <0.05) in A group, however, comparing in the condition under 50 kg patients, they showed no significant differences and the quality was tolerable for diagnosis in both group. Conclusion : This demonstrates the difficulty to perform the high-quality CT with a reduced CM in SDCT. However, this does not negate the diagnostic ability of low dose of CM, but reflects the importance of determining the acceptable lowest doze of CM for diagnosis.
- 2004-05-25