Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic Scoliosis
スポンサーリンク
概要
- 論文の詳細を見る
This is a non-final version of an article published in final form in SPINE 35(3): 347-352, 2010.Study Design. Retrospective clinical study. Objective. To assess the accuracy of multilevel registration for skip pedicle screw placement during image-guided, computer-assisted spine surgery, in the setting of adolescent idiopathic scoliosis (AIS). Summary of Background Data. Computerized frameless stereotactic image-guidance has been used recently to improve pedicle screw placement accurately and safety during spine surgery. Because of possible intervertebral motion and usual difference in patients' position between preoperative imaging and surgery, the imaging model and the surgically exposed spine may be significantly discordant. Consequently, current protocols suggested separate registration of each spinal level (single-level registration) before respective pedicle screw placement, a time-consuming process. Moreover, although multilevel registration for lumbar spine has been reported, and that for thoracic spine has not. Methods. A total of 19 patients ( 1 male and 18 females; mean age, 13.9 years) with AIS who underwent multilevel registration for skip pedicle screw placement were included. Variables including surgical time, blood loss, preoperative and 2-year postoperative Cobb angle, correction rate, and postoperative screw position by computed tomography image were evaluated. Mean registration error after point merge and again after surface merge were recorded for each consecutive vertebra of each case. Results. Mean surgical time was 310 minutes ( range, 168-420 min). Mean blood loss 1138 g (range, 300-2300 g). Cobb angle before operation and at 2 years postoperation was 62.4 degrees (43 degrees-100 degrees) and 21.6 degrees (9 degrees-42 degrees), respectively. Mean correction rate 66.2% (39.7%-84.5%). Total 265 screws were inserted with computed tomography-based navigation system. Pedicle violation was observed in only 4 screws (1.5%). No neurovascular complication occurred. After point merge, average Mean registration error of all cases was 1.69 +/- 0.52 mm, and after surface merge was 0.51 +/- 0.16 mm. Conclusion. Multilevel registration may decrease operative time without compromising accuracy of pedicle screw placement afforded by this technique in the setting of AIS.http://journals.lww.com/spinejournal/pages/default.aspx
- 2010-02-01
論文 | ランダム
- 高等学校における地理の学習実態に関する考察--大学生へのアンケート調査をもとに
- 群馬県南西部における乗合バス・代替バス事業と路線網の変遷
- 中国華東地域における陸上交通
- 2点配位型ルイス酸触媒の機能開発 (有機合成化学の新潮流) -- (触媒における新潮流)
- アルミニウム (金属反応剤を用いる不斉化学合成) -- (典型金属の特性を活かした不斉合成)