A new formulation of laser step diagonal measurement—Three-dimensional case
スポンサーリンク
概要
- 論文の詳細を見る
To ensure the motion accuracy of a machine tool over its entire three-dimensional workspace, it is important to evaluate all the volumetric errors associated with three linear axes including three linear displacement errors, six straightness errors and three squareness errors. The laser step diagonal measurement modifies the diagonal displacement measurement, described in the standard ISO 230-6, by executing a diagonal as a sequence of single-axis motions. It has been claimed that the step diagonal test enables the identification of all the volumetric error components by using a linear laser interferometer only. This paper first shows that the conventional formulation of step diagonal measurements is potentially subject to a significant estimation error caused by setup errors in mirror and laser directions. We then propose a new formulation of laser step diagonal measurement, in order to accurately identify three-dimensional volumetric errors even under the existence of setup errors. The effectiveness of the modified identification scheme is experimentally investigated by an application example of three-dimensional laser step diagonal measurements to a high-precision vertical machining center.© 2010 Elsevier B.V.
論文 | ランダム
- DHAの生理機能(機能性脂質生産の新たなターゲットを探る)
- Pseudoalteromonas sp. Strain No. 1786 菌株が産出するアルギン酸リアーゼの単離と諸性質
- 2S2AM6 DHAの生理機能(機能性脂質生産の新たなターゲットを探る,シンポジウム)
- DHA摂取による高脂血症治療効果
- 水産物資源を利用した特定保健用食品の開発 (特集1 水産物資源の活用技術)